Bituminous-Membrane-Waterproofing

Submission of Missing Details for Waterproofing in our Previous Submittal

Date: xxx

Ref. xxx

To:

M/s. xxx Consulting Architects and Engineers

Dubai, UAE

Kind Attn:     Mr. xxx

Project:          2B + G + 14+ Lower Roof Hotels Building on Plot No. xxx at Barsha, Dubai.

Subject:             Submission of Missing Details for Waterproofing in our Previous Submittal CC/AP/269/07/27B  Dt :xx

Dear Sir,

            With reference to the above mentioned subject, in our previous submittal there are some information remain silent or kept blank , kindly find here with the missing information in our comparative statement submitted by Henkel  letter # HPIL/TCS/15327/2015, please note the following

S.noPropertiesFlexobitBituplus EX 4180As per site Specification 2 layer applicationRemarks
Item  # 03Thickness (mm)5.0+0.34In specification 5mmContractor proposal 4 + 4= 8mm
Item # 05Water tightness to liquid water (kpa)3005 bar @ 50m The Bituplus EX 4180 excellent resistance to positive water & vapor Pressure
Item # 06Elongation at break length direction100040/50 Flexobit is 1000%  because of  non –reinforcement homogeneous pure bitumen but Bituplus EX 4180 40% because of  mixture of bitumen and SBS polymer as well it have stable reinforcement core of non woven spun bond ployster rot-proof fabric
S.NoPropertiesFlexobitBituplus EX 4180As per site Specification 2 layer applicationRemarks
Item  # 09Flow Resistance at elevated temperature90No flow till 100 degree centigrade  
Item # 12Reaction to FireFFl Both the materials by product of the petrol chemical (No fire resistance)

So kindly find the missing information for your kind comparison and further explanation & enabling to comparison to avoid any comments for because of missing item