November 2022

INSTALLATION OF LIGHTNING PROTECTION SYSTEM

Method Statement Title: Testing of Lightning Protection System

Method Statement Title: Testing of Lightning Protection System 1.0       Scope 1.1       Testing of Lightning protection system in accordance with the requirements of                       Specification 16950. 2.0       Material 3.0       Method 3.1       Testing equipment   4.1.1    Earth tester.  4.1.2    Continuity tester.                          The calibration certificates of testing instruments will be verified for validity                        prior to use. […]

Method Statement Title: Testing of Lightning Protection System Read Post »

Risk Assessment for Emergency Lighting system

Method Statement Title: Testing and Commissioning of Emergency Lighting System

Method Statement Title: Testing and Commissioning of Emergency Lighting System 1.0       Scope This method statement details the Testing and Commissioning of Emergency Lighting System, as per Project Specification 16536             Note             A separate Method Statement Ref. ETA/MS/E- 014 shall be submitted for Installation of  the Emergency Lighting System. 2.0       Material 2.3       Type of emergency

Method Statement Title: Testing and Commissioning of Emergency Lighting System Read Post »

METHOD STATEMENT FOR WIRES AND CABLES INSTALLATION

Method Statement Title: Testing of LV Cables / Wires

Method Statement Title: Testing of LV Cables / Wires 1.0       Scope 2.0       Material 3.0       Testing Equipment Note : The Calibration certificates of testing instruments shall be verified to have current certificate, prior to usage. 4.0       Testing and Commissioning Method 4.1       Physical Checks 4.2       Insulation Resistance Test 5.0       Records 5.1       Inspection request duly signed-off by NMX

Method Statement Title: Testing of LV Cables / Wires Read Post »

METHOD STATEMENT FOR EARTHING SYSTEM INSTALLATION

Method Statement Title: Installation of Lightning Protection system

Method Statement Title: Installation of Lightning Protection system 1.0      Scope : 2.0      Material : Material used for the system is as per BS 6651 : 1992.  3.0      Applicable locations :             Roof, Basement, and ground level network.  4.0      Method : Material shall be stored in a covered/dry space at all the

Method Statement Title: Installation of Lightning Protection system Read Post »

Risk Assessment for Emergency Lighting system

Method Statement Title: Testing and Commissioning of Fire Alarm System

Method Statement Title: Testing and Commissioning of Fire Alarm System 1.0       Scope This method statement details the method of Testing and commissioning of  Fire Alarm  System, as per Project Specification 16721             Note             A separate Method Statement Ref. ETA/MS/E- 018 shall be submitted for Installation of  the Fire Alarm System. 2.0       Material 2.3       Type

Method Statement Title: Testing and Commissioning of Fire Alarm System Read Post »

METHOD STATEMENT FOR FIRE ALARM SYSTEM INSTALLATION

Method Statement Title: Installation of Fire Alarm System

Method Statement Title: Installation of Fire Alarm System 1.0       Scope This method statement details the method of installation of Fire Alarm  System, as per Project Specification 16721             Note             A separate Method Statement Ref. ETA/MS/E- 033 shall be submitted for testing and commissioning of the Fire Alarm System. 2.0       Material 2.3       Type of FA

Method Statement Title: Installation of Fire Alarm System Read Post »

METHOD STATEMENT FOR WIRES AND CABLES INSTALLATION

Method Statement Title: Installation of Cables and Wires

Method Statement Title: Installation of Cables and Wires 1.0       Scope Note: 1) Refer method statement Ref. No ETA/MS/E-005 for installation of cable trays and ladders. 2.0       Material 3.0       Applicable Location             3.1       Tower E1, E2, E3, W1, W2, W3, Podium and Villas. 4.0       Method 4.1       Storage   4.1.1    All materials received at site shall be

Method Statement Title: Installation of Cables and Wires Read Post »

METHOD STATEMENT FOR WIRES AND CABLES INSTALLATION

Method Statement Title: Installation of Emergency Lighting System

1.0       Scope This method statement details the method of installation of Emergency Lighting System, as per Project Specification 16536             Note             A separate Method Statement Ref. ETA/MS/E- 034 shall be submitted for testing and commissioning of the Emergency Lighting System. 2.0       Material 2.3       Type of emergency / exit luminaire shall be as per approved

Method Statement Title: Installation of Emergency Lighting System Read Post »

METHOD STATEMENT FOR ELECTRICAL IDENTIFICATIONS INSTALLATION

Method Statement Title: Installation of CO detection and Alarm System

Method Statement Title: Installation of CO detection and Alarm System 1.0       Scope This method statement details the method of installation of CO detection and alarm system. NOTE :           1. Testing and Commissioning of CO Detection and Alarm system will be submitted separately under Ref. ETA/MS/E-007. 2.0       Material 3.0       Applicable Location and First Floor) 4.0       Method

Method Statement Title: Installation of CO detection and Alarm System Read Post »

METHOD STATEMENT FOR WIRES AND CABLES INSTALLATION

Method Statement Title: Installation of Cable Trays and Ladders

Method Statement Title: Installation of Cable Trays and Ladders 1.0       Scope 1.1       This method statement details the method of installation of cable trays and ladders. 2.0       Material 2.1       Cable trays and ladders and accessories shall be as per approved material submittal.  3.0       Applicable Location 3.1       Tower E1, E2, E3, W1, W2, W3 and Podium –

Method Statement Title: Installation of Cable Trays and Ladders Read Post »