Method of Statement

3-tips-for-Fire-Pump

Method Statement Title: Testing & Commissioning of Fire Protection System

Method Statement Title: Testing & Commissioning of Fire Protection System Scope : This scope of this method statement covers the testing and commissioning of sprinklers and Wet Riser system within the Burj Dubai – The Residences in accordance with the following. Note: Method statement for the startup and commissioning of fire pump set will be […]

Method Statement Title: Testing & Commissioning of Fire Protection System Read Post »

3-tips-for-Fire-Pump

Method Statement Title: Start-up and Commissioning of Fire Water Pumps

Method Statement Title: Start-up and Commissioning of Fire Water Pumps Scope The scope of this Method Statement is to define the method of Start-up and Commissioning of Fire Water Pumps installed within Burj Dubai – The Residences, in accordance with the Specification Sections 15500 applicable NFPA and manufacturer’s instructions attached.             Note 2.0       Material            

Method Statement Title: Start-up and Commissioning of Fire Water Pumps Read Post »

CHECKLIST FOR INSTALLATION OF SUMP PUMP

Method Statement Title: Start up & Commissioning of Sump Pumps

Method Statement Title: Start up & Commissioning of Sump Pumps Scope The scope of this Method Statement is to define the method of Start-up and Commissioning of Sump Pumps installed within the Burj Dubai – The Residences, in accordance with the Specification Sections 15440 manufacturer’s instructions attached.             Note a.         For installation of Sump Pumps

Method Statement Title: Start up & Commissioning of Sump Pumps Read Post »

Method Statement for Installation of Electric Water Heater

Method Statement Title: Installation of Water Heaters

Method Statement Title: Installation of Water Heaters Scope 1.1       This method statement applies to installation of water heaters as approved. 2.0       Purpose 2.1       Purpose of this method statement is to outline the method of storage, handling and installation of water heaters and pertaining accessories. 3.0       Material              3.1       Ceiling mounted water heaters             3.2       Pressure

Method Statement Title: Installation of Water Heaters Read Post »

METHOD STATEMENT FOR INSTALLATION AND TESTING OF FIRE SPRINKLER SYSTEM

Method Statement Title: Installation of Sprinkler Piping System

Method Statement Title: Installation of Sprinkler Piping System Scope The scope of this method statement is to describe the method of installation of sprinkler piping system in Burj Dubai – The Residences Project in accordance with the project specifications.             Note a.         Installation of stand pipes and fire hose reels is covered under a separate

Method Statement Title: Installation of Sprinkler Piping System Read Post »

3-tips-for-Fire-Pump

Method Statement Title: Installation of Fire Water Pumps

Method Statement Title: Installation of Fire Water Pumps Note             A separate method statement Ref. ETA/MS/P-015 will be submitted for Start-up & Commissioning of Fire Water Pumps. 4.0       Applicable Location                 4.1       West Tower – W2 Basement Floor. 5.0       Method 5.1       Receiving 5.1.1    When received at site, each pump, valves, air vent, pressure relief valve

Method Statement Title: Installation of Fire Water Pumps Read Post »

uPVC High Pressure Water Supply Piping System Installation Procedure

Method Statement Title: Installation & Testing of Underground Drainage Piping

Method Statement Title: Installation & Testing of Underground Drainage Piping 1.0       Scope 1.1       This method statement details the method for installation and hydrostatic testing of underground drainage piping. 2.0       Material             2.1       UPVC Pipes to EN1401-1 (Formerly BS 4660) with push-fit grooved joints. 3.0       Applicable Location             East and West Podium – Basement level. 4.0      

Method Statement Title: Installation & Testing of Underground Drainage Piping Read Post »