Study Materials

๐—ฃ๐—ฟ๐—ถ๐—บ๐—ฎ๐˜ƒ๐—ฒ๐—ฟ๐—ฎ ๐—ฃ๐Ÿฒ ๐—ฑ๐—ฎ๐˜๐—ฒ ๐—ฐ๐—ผ๐—ป๐˜€๐˜๐—ฟ๐—ฎ๐—ถ๐—ป๐˜๐˜€

๐—ฃ๐—ฟ๐—ถ๐—บ๐—ฎ๐˜ƒ๐—ฒ๐—ฟ๐—ฎ ๐—ฃ๐Ÿฒ ๐—ฑ๐—ฎ๐˜๐—ฒ ๐—ฐ๐—ผ๐—ป๐˜€๐˜๐—ฟ๐—ฎ๐—ถ๐—ป๐˜๐˜€

๐—ฃ๐—ฟ๐—ถ๐—บ๐—ฎ๐˜ƒ๐—ฒ๐—ฟ๐—ฎ ๐—ฃ๐Ÿฒ, ๐—ฑ๐—ฎ๐˜๐—ฒ ๐—ฐ๐—ผ๐—ป๐˜€๐˜๐—ฟ๐—ฎ๐—ถ๐—ป๐˜๐˜€ are used to specify when an activity should start or finish.They help control the scheduling of activities by imposing restrictions based on specific dates. Here are the main ๐—ฑ๐—ฎ๐˜๐—ฒ ๐—ฐ๐—ผ๐—ป๐˜€๐˜๐—ฟ๐—ฎ๐—ถ๐—ป๐˜๐˜€ ๐—ฎ๐˜ƒ๐—ฎ๐—ถ๐—น๐—ฎ๐—ฏ๐—น๐—ฒ ๐—ถ๐—ป ๐—ฃ๐—ฟ๐—ถ๐—บ๐—ฎ๐˜ƒ๐—ฒ๐—ฟ๐—ฎ ๐—ฃ๐Ÿฒ: ๐Ÿญ. ๐—ฆ๐˜๐—ฎ๐—ฟ๐˜ ๐—ข๐—ป (๐—ฆ):Activities with a Start On constraint must start on a specific date specified by […]

๐—ฃ๐—ฟ๐—ถ๐—บ๐—ฎ๐˜ƒ๐—ฒ๐—ฟ๐—ฎ ๐—ฃ๐Ÿฒ ๐—ฑ๐—ฎ๐˜๐—ฒ ๐—ฐ๐—ผ๐—ป๐˜€๐˜๐—ฟ๐—ฎ๐—ถ๐—ป๐˜๐˜€ Read Post ยป

subcontractor contract agreement.

Types of Construction Contracts

1 โ€“ Lumpsum Contract In a lump sum contract, the engineer or/and contractor agrees to do the specified project for a fixed price. Also called โ€œfixed fee contracts,โ€ these are often used for engineering ventures.A lump sum or fixed fee contract is appropriate if the scope and schedule of the project are sufficiently defined to

Types of Construction Contracts Read Post ยป

Method statement of fixing of Electrical light

Electrical Thumb Rules-(Part 1).

Cable Capacity: โ€ข For Cu Wire Current Capacity (Up to 30 Sq.mm) = 6X Size of Wire in Sq.mm โ€ข Ex. For 2.5 Sq.mm=6ร—2.5=15 Amp, For 1 Sq.mm=6ร—1=6 Amp, For 1.5 Sq.mm=6ร—1.5=9 Amp โ€ข For Cable Current Capacity = 4X Size of Cable in Sq.mm ,Ex. For 2.5 Sq.mm=4ร—2.5=9 Amp. โ€ข Nomenclature for cable Rating

Electrical Thumb Rules-(Part 1). Read Post ยป

Critical Path

Aligning the Primavera P6 program with actual site conditions

Aligning the Primavera P6 program with actual site conditions entails updating the project schedule to reflect the current progress and circumstances on the construction site. This ensures the program accurately mirrors the project’s status, facilitating effective project management. Here’s how you can synchronize the Primavera P6 program with real site conditions: Aligning the Primavera P6

Aligning the Primavera P6 program with actual site conditions Read Post ยป

Design Guidelines of Pressurized Air Compressor Rooms in Hot & Humid Climates.

MEP Design Guidelines of Pressurized Air Compressor Rooms in Hot & Humid Climates.

The area designated for compressors, known as the compressor room, constitutes a crucial component of the compressed air system. It may be a specialized room solely for compressor use or a multifunctional space. Regardless, specific criteria should be met to optimize the compressor setup. Centralizing the compressor plant is generally recommended, as it offers diverse

MEP Design Guidelines of Pressurized Air Compressor Rooms in Hot & Humid Climates. Read Post ยป