Installation Check List For Capacitor Banks.
Installation Check List For Capacitor Banks.
Installation Check List For Capacitor Banks. Read Post »
Installation Check List For Capacitor Banks.
Installation Check List For Capacitor Banks. Read Post »
Installation Check List For Enclosed Bus Duct System
Installation Check List For Enclosed Bus Duct System Read Post »
Installation Check List For ATS
Installation Check List For ATS Read Post »
METHOD STATEMENT WIRING DEVICES SECOND FIX INSTALLATION & WIRING TERMINATION I. MATERIALS TO BE USED SWT1CHES & ACCESSARIES: 1.10A, 1 Gang, 1 Way. 250 V 2.10A, 2 Gang. 1 Way. 250 V 3.10A, 1 Gang, 1 Way, 220 V, Push button for Door Bell. 4.10A, 1 Gang. 1 Way, 220 V. Push button with label
METHOD STATEMENT WIRING DEVICES SECOND FIX INSTALLATION & WIRING TERMINATION Read Post »
METHOD OF STATEMENT FOR ELECTRIC WATER HEATER INSTALLATION
METHOD OF STATEMENT FOR ELECTRIC WATER HEATER INSTALLATION Read Post »
MATERIAL TO BE USED:- Telephone terminal cabinet is made of steel enclosure with size 150 x 150 x 100 mm with sufficient knock outs and front door with lock. This cabinet is flush mounted with labeling sheet equipped with relevant terminal block and have 20 % spare for future expansion and wiring for extra terminal
METHOD STATEMENT FOR TTC TERMINAL INSTALLATION AND TELEPHONE WIRING TERMINATION Read Post »
MATERIAL TO BE USED:- Power Cables are of stranded cu conductor multicore XLPE insulated PVC sheathed feeder cables 0.6/lKV of 90°C temperature manufactured by Jeddah Cables. Telephone wires and cables 2 and 12 paired are multi paired indoor type solid plain copper conductor 0.6 mm dia PVC insulated and shielded, manufactured by Amaco cables. Intercom
MATERIAL TO BE USED:- Galvanized steel back boxes, 7cm x 7cm x 4.7cm depth 1.1 mm wall thickness with Earth terminals are used for wiring devices as back boxes Eletra make. For panel enclosure metallic enclosures zinc coated 1,2mm thick with epoxy painting ivory color and with required knock out is provided Merlin Gerin make
TV SPLITTER INSTALLATION AND WIRING TERMINATIONS MATERIAL TO BE USED:- Flush mounted TV splitter metal enclosure with size 150xl50xlOOmm manufactured by Eletra with sufficient knock outs and frame to install 2 way splitter and 6 way splitter in this enclosure. RG 6 – C5760 Coaxial Cable is installed between individual TV outlets and 6 way
METHOD STATEMENT FOR TV SPLITTER INSTALLATION AND WIRING TERMINATIONS Read Post »
METHOD OF STATEMENT FORWATER SUPPLY PIPE INSTALLATION INSIDE THE TOILET b-9. While both the inside socket surface and the outside surface of the pipe are soft and wet with solvent cement, forcefully bottom the pipe in the socket, giving the pipe a one-quarter turn, if possible. The pipe must go to the bottom of the
METHOD OF STATEMENT FOR WATER SUPPLY PIPE INSTALLATION INSIDE THE TOILET Read Post »